4-Series Induction Ranges
Firmware update for enhanced performance and reliability
New firmware now available for your Vollrath 4-series Induction Range. Update your unit now to get the latest and greatest in technology and features.
- Enhanced dry pan protection mode
- Improved performance during temperature recovery mode when cooking larger volumes such as pasta or deep frying
- Optimized fan speed control for internal cooling and off state noise reduction
- Models to update: MPI4-1800S, MPI4-1440S, HPI4-2600, HPI4-3000, HPI4-3800
FIRMWARE UPDATE INSTRUCTIONS (Version 5.0 | Release Date: 11/3/2021)
Remove USB jump drive from induction unit
- Remove USB drive from induction range and insert USB drive into computer
- DOWNLOAD FIRMWARE HERE
- Unzip/uncompress the downloaded file and copy the “.lux” file from the Induction Range folder onto the USB jump drive
- Unplug induction range
- Insert USB jump drive (with files on it) into induction range
- Plug induction range back in
- Wait for unit to start downloading program by displaying SSS , UUU
- After “A02,” remove USB jump drive from unit
- Unplug induction range, wait for “Vollrath” light to turn off
- Plug induction range back in and use.
- Delete file from USB jump drive using your computer, then insert back into induction range, screw on cover for safe keeping
Please contact Becky Guentner with any questions.